Capricorn Wyse Terminal Set up Procedure

The Wyse terminal is used for debug, and installing new Capricorn system software - during the boot, the Storage node sends debug information out of its RS232 connector.

 

Wyse Terminal WY-150/ES enhanced style PC keyboard

Shift & Select to go into Setup mode

F1 (DISP) |
COLUMNS = 80 |CURSOR    = BLINK BLK ||SCRN SAVER = ON
LINES       = 25 |DISPLAY    = DARK ||CHAR CELL    = 10 x 16
PAGE       = 1 x Lines |AUTOPAGE = OFF ||80/132 CLR     = OFF

Use SPACE BAR or BACKSPACE to change parameters.

F2 (GENRL) |
PERSONALITY = VT100 |ENHANCE    = OFF ||STATUS LINE       = ON
SCRL                = JUMP |AUTO SCRL = ON ||WRAP EOL           = OFF
RCV CR           = CR |MONITOR     = OFF ||RECOGNISE DEL = ON

 

F3 (KEYBD) |
KEYCLICK   = ON |REPEAT         = ON |KEYCODE        = ASCII
KEYLOCK   = CAPS |MARGIN BELL = OFF |BELL VOLUME = I
LANGUAGE = ENGLISH |CORNER KEY = COMPOSE |

 

F4 (COMM) |
BAUD RATE = 9600 |DATA/PARITY              = 8/NONE |STOP BITS     = 1
RCV HDSHK = NONE |RCV HNDSHK LEVEL = 192 |XMT HNDSHK = NONE
COMM         = FDX |XMT LIM                      = NONE |HOST PORT   = SERIAL 2

 

F5 (MISC) |
WP RT INTENSITY     = DIM |WPRT REV                = OFF |WPRT UNDRLN   = OFF
BLK END                   = US/CR |ATTRIBUTE                 = CHAR |MULTIPLE PAGE = ON
PRINTER ATTACHED = ON |NULLS SUPPRESS    = ON

 

F6 (ANSI 1) |
CHAR SET          = ISO LATIN-1 |CHAR MODE = NATIONAL |ANSI ID    = VT100
CURSOR KEYS  = NORMAL |KEYPAD       = NUMERIC |DEL         = DEL/CAN
FEATURE LOCK = OFF |FKEY LOCK  = OFF |NEWLINE = ON

 

F7 (ANCII) |
PRINT          = ASCII |PRINT AREA                = SCREEN |PRINT TERM = NONE
SEND          = ALL |SEND AREA                = SCREEN |SEND TERM = NONE
XFER TERM = EOS |AUTO ANSWERBACK = OFF |KEYS            = TYPEWRITER

 

F11 (PRNTR) |
BAUD RATE = 9600 |DATA/PARITY = 8/NONE |STOP BITS = 1
PRINTER      = PARALLEL

F12 Exit

SAVE

F12 to EXIT